Please use this identifier to cite or link to this item: http://digitalrepository.fccollege.edu.pk/handle/123456789/1191
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLee, H.-
dc.contributor.authorChung, Shinho-
dc.contributor.authorYu, M.-
dc.contributor.authorKoo, J.-
dc.contributor.authorHyun, I.-
dc.contributor.authorLee, H.-
dc.date.accessioned2021-04-14T08:05:08Z-
dc.date.available2021-04-14T08:05:08Z-
dc.date.issued2005-11-
dc.identifier.citationH. Lee, S. Chung, M. Yu, J. Koo, I. Hyun, H. Lee; Applicable background minimum night flow for leakage management of small district metered areas in Korea. Water Supply 1 November 2005; 5 (3-4): 181–188. doi: https://doi.org/10.2166/ws.2005.0098en_US
dc.identifier.otherhttps://doi.org/10.2166/ws.2005.0098-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/1191-
dc.descriptionhttps://iwaponline.com/ws/article/5/3-4/181/26060/Applicable-background-minimum-night-flow-foren_US
dc.description.abstractIn case of Seoul city in Korea, the level of water leakage from any distribution system is evaluated by comparison of measured minimum night flows (NFMs) with a fixed allowable leakage level. However, infrastructure condition of District Metered Areas (DMAs) could be misjudged, because characteristics of the system are not considered properly. Therefore the components of NFM were estimated in residential and business DMAs by using data of night uses collected by modified option A test and real losses from water balance analysis. A new background minimum night flow equation was developed by the components of NFM. Applicability of the equation was tested on various revenue water % residential and business DMAs. As a result, it is concluded that the new background night flow developed in this study is more reasonable in Korea and could be used to judge whether the DMAs have economically recoverable unreported bursts prior to leakage detection activity.en_US
dc.language.isoenen_US
dc.publisherIWA publishingen_US
dc.relation.ispartofseriesWater Supply 1 November 2005; 5 (3-4): 181–188;-
dc.subjectminimum night flowen_US
dc.subjectAllowable leakage;en_US
dc.subjectbackground minimum night flow;en_US
dc.subjectleakage detection;en_US
dc.titleApplicable background minimum night flow for leakage management of small district metered areas in Koreaen_US
dc.typeArticleen_US
Appears in Collections:Environmental Science Department

Files in This Item:
File Description SizeFormat 
Applicable background minimum night flow for leakage management_[Lee.2005].pdf507.47 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.